Skip to main content
Industrial supply network
IMB Electric
B2B · PRODUCT SERIES · GLVAC
LIVE

GLVAC · PRODUCT SERIES

GLVAC Vacuum Interrupter for Circuit Breaker

1.14-40.5 kV, 400A-2000A core component of medium-voltage circuit breakers — TD series vacuum interrupter tubes

The GLVAC TD Series vacuum interrupter tubes are the core element of medium-voltage circuit breakers (CB). Unlike AC contactor vacuum interrupters, circuit breaker tubes are optimized for short-circuit fault current interruption — safely interrupting fault currents at high kA values in milliseconds.
15 models span 6 voltage classes:
  • 1.14 kV (2 models)
  • 7.2 kV (1 model)
  • 12 kV (8 models: 630-2000 A, 20-31.5 kA breaking)
  • 24 kV (1 model)
  • 36 kV (2 models)
  • 40.5 kV (1 model)

Each model offers 30 rated breaking cycles. Lightning impulse withstand voltage of 18-185 kV (model-dependent) protects against system overvoltages.

Typical customers: medium-voltage circuit breaker manufacturers (vacuum circuit breaker VCB makers), city distribution panel manufacturers, and industrial switchgear manufacturers.
Medium-voltage circuit breaker (VCB) manufacturersCity distribution panel manufacturersIndustrial switchgear manufacturersMV substation equipmentGrid protection systems
01type
Devre kesici çekirdek bileşeni vakum kesici tüpü
02Current Range
400 A – 2000 A nominal
03voltage classes
1.14 / 7.2 / 12 / 24 / 36 / 40.5 kV (6 sınıf)
04rated breaking times
30 çevrim
05breaking current range
8 – 31.5 kA
06lightning impulse withstand
18 – 185 kV (model dependent)
01

Vacuum Interrupter for Circuit Breaker Series Contactor Models

Sorted by current rating (150A → 1000A)

15 MODELS
MODELcurrentrated current arated voltage kvbreaking current kalightning impulse kvwithstand voltage kv
4001.1481810
6301.14151810
125012207542
125012257542
12501231.57542
16001231.57542
20001226.38548
63012207542
63012207542
63012257542
1250242012565
1250362018595
20003626.318595
125040.52018595
6307.212.56032

TECHNICAL DIFFERENTIATORS

Why DEVRE-KESICI-ICIN-VAKUM-KESICI Series?

Maintenance-Free Performance

  • Vacuum insulation

    No oil or gas replacement needed.

  • Long service interval

    Ideal for city distribution infrastructure.

High BIL (Lightning Impulse) Protection

  • 18-185 kV BIL

    Lightning and line switching overvoltage protection.

  • 6 voltage classes

    Optimum BIL for every system voltage.

High Short-Circuit Breaking

  • 8-31.5 kA breaking current

    Safely interrupts high fault currents.

  • 30-cycle life

    Optimum for circuit breaker operation profile.

DATASHEET · GUIDE · APPLICATION NOTE

DEVRE-KESICI-ICIN-VAKUM-KESICI Series — Technical Resources

TD-1.14/400-8 Datasheet

  • TD-1.14/400-8 DatasheetSOON

TD-1.14/630-15A Datasheet

  • TD-1.14/630-15A DatasheetSOON

TD-7.2/630-12.5E Datasheet

  • TD-7.2/630-12.5E DatasheetSOON

TD-12/630-20C Datasheet

  • TD-12/630-20C DatasheetSOON

TD-12/630-20D Datasheet

  • TD-12/630-20D DatasheetSOON

TD-12/630-25A Datasheet

  • TD-12/630-25A DatasheetSOON

TD-12/1250-20 Datasheet

  • TD-12/1250-20 DatasheetSOON

TD-12/1250-25J Datasheet

  • TD-12/1250-25J DatasheetSOON

TD-12/1250-31.5J Datasheet

  • TD-12/1250-31.5J DatasheetSOON

TD-12/1600-31.5A Datasheet

  • TD-12/1600-31.5A DatasheetSOON

TD-12/2000-26.3 Datasheet

  • TD-12/2000-26.3 DatasheetSOON

TD-24/1250-20 Datasheet

  • TD-24/1250-20 DatasheetSOON

TD-36/1250-20 Datasheet

  • TD-36/1250-20 DatasheetSOON

TD-36/2000-26.3 Datasheet

  • TD-36/2000-26.3 DatasheetSOON

TD-40.5/1250-20A Datasheet

  • TD-40.5/1250-20A DatasheetSOON

FREQUENTLY ASKED QUESTIONS

About the DEVRE-KESICI-ICIN-VAKUM-KESICI series

RELATED INSIGHTS · DEVRE-KESICI-ICIN-VAKUM-KESICI
LIVE

RELATED INSIGHTS

Go deeper

02 ENTRIES

// end of index · 02 / 02