Skip to main content
Industrial supply network
IMB Electric
GLVAC CV / CHV Series — Mining low-voltage (CV sub-group)
B2B · PRODUCT SERIES · GLVAC
LIVE

GLVAC · PRODUCT SERIES

GLVAC CV / CHV Series

1.14 kV to 3.6 kV modular design AC vacuum contactor — wide range from 80A to 450A

The GLVAC CV/CHV Series offers different voltage and current combinations under a single family using a modular design approach. The CV sub-group (CV-80, CV-160) is designed for 1.14 kV mining and low-voltage industrial applications; the CHV sub-group (CHV-400/3.3, CHV-450/1.14, CHV-450/3.6) for medium-voltage and high-fault-current protection applications.
The CHV-450/1.14 model is particularly notable with its 26000 A limited breaking capacity — approximately 5-10 times the industry average, providing safe interruption in scenarios like large transformer rear short-circuit faults. The 0.3 million mechanical life in CHV series indicates reduced operation frequency (emergency-cut-off focused).
Typical applications: mining (CV-80/1.14, CV-160/1.14), petrochemical medium-voltage drives (CHV-400/3.3), high-fault-current industrial circuits (CHV-450/1.14), railway and metallurgy (CHV-450/3.6).
Mining low-voltage (CV sub-group)Petrochemical medium-voltage drives (CHV-400/3.3)High-fault-current industrial circuitsRailway power distribution (CHV-450/3.6)Metallurgy arc furnace drivesLarge transformer protection circuits
01type
Modüler tasarım AC vakum kontaktör
02Sealing
Vakum yalıtımlı kontak
03frequency
AC 50 Hz
04Current Range
80 A – 450 A (5 model)
05Voltage Rating
1.14 / 3.3 / 3.6 kV
06electrical life
0.3 – 1 milyon çevrim (model dependent)
07limited breaking capacity
26000 A (CHV-450/1.14)
01

CV / CHV Series Series Contactor Models

Sorted by current rating (150A → 1000A)

5 MODELS
MODEL↑ currentsub grouprated making arated current arated breaking arated voltage kvmechanical life mlimited breaking a
CHV400040032003.314000
CHV450045036001.140.326000
CHV450045036003.60.313000
CV192016016001.1413000
CV980808001.1412000

TECHNICAL DIFFERENTIATORS

Why CV-CHV Series?

High Fault Current Protection (26000 A)

  • CHV-450/1.14 — 26000 A

    → 5-10x industry average.

  • Transformer, arc furnace, lightning protection

    → Critical safety.

Vacuum-Insulated Structure

  • Arc interruption in vacuum

    → Safe interruption at high fault current.

  • Sealed housing

    → Resistant to industrial and mining environments.

Modular Design (CV + CHV)

  • CV + CHV two sub-groups

    → Standard and high-protection applications.

  • 1.14 / 3.3 / 3.6 kV wide range

    → Different system voltages.

DATASHEET · GUIDE · APPLICATION NOTE

CV-CHV Series — Technical Resources

CV-80/1.14 Datasheet

  • CV-80/1.14 DatasheetSOON

CV-160/1.14 Datasheet

  • CV-160/1.14 DatasheetSOON

CHV-400/3.3 Datasheet

  • CHV-400/3.3 DatasheetSOON

CHV-450/1.14 Datasheet

  • CHV-450/1.14 DatasheetSOON

CHV-450/3.6 Datasheet

  • CHV-450/3.6 DatasheetSOON