HV Hermetic Design
Sealed contact chamber
Vacuum / gas-filled construction — consistent arc extinction independent of environment.
12 / 24 / 48 / 110 Vdc coil
Directly compatible with industrial and mobile DC bus voltages.

Sensata | Gigavac · PRODUCT SERIES
8 models · 8-25 kVdc switching · 10-150 A continuous · Two ganged Form C contacts on one coil · Polarity reversal, multi-channel switching, transfer
Certifications vary by model — see the corresponding model datasheet for details.

DPDT Series 2 form c Contactor Models
Sorted by current rating (150A → 1000A)
| CONFIGURATOR | MODEL↑ current | Contact Voltage (kV) | Continuous Current (A) | Mounting Types | |
|---|---|---|---|---|---|
G12 | 8kV | 10 | — | — | |
G13 | 15kV | 10 | — | — | |
G15SPD | 15kV | 12 | — | — | |
G2SPD | 15kV | 50 | — | — | |
G8SPD | 15kV | 30 | — | — | |
G53 | 25kV | 150 | — | — |
Latching Models
2 models · Holds state without continuous coil power
| CONFIGURATOR | MODEL | Contact Voltage (kV) | Continuous Current (A) | Mounting Types | |
|---|---|---|---|---|---|
G12L | 8kV | 10 | — | Datasheet (PDF) — G12L | |
G13L | 15kV | 10 | — | Datasheet (PDF) — G13L |
STEP-BY-STEP CONFIGURATION
Pick token by token following the manufacturer's coding table; we'll generate the exact part number and open a tailored datasheet.
TECHNICAL DIFFERENTIATORS
Sealed contact chamber
Vacuum / gas-filled construction — consistent arc extinction independent of environment.
12 / 24 / 48 / 110 Vdc coil
Directly compatible with industrial and mobile DC bus voltages.
A/B dual-pole source selection
Single assembly that transfers both positive and negative rails simultaneously — for redundant power.
Symmetric battery pack disconnect
In bipolar battery architectures cuts both poles simultaneously as the main disconnect.
10 A — 150 A continuous current scale
G12, G13 (10 A) low-current signal/measurement; G53 (150 A) for railway and industrial main lines.
8 kV — 25 kV voltage range
Covers the majority of EV, railway, industrial HV and test equipment within a single family.
G12L · G13L pulse-latching DPDT
Dual-pole versions without continuous coil power for low-power-budget systems.
Position retained on coil loss
In some safety philosophies retaining the current position is the desired behaviour.
Two independent Form C in one mechanism
Positive and negative lines switch in mechanical sync — no sub-millisecond mismatch.
Line-to-line short protection
Dual-pole simultaneity is guaranteed — no protection-relay misjudgement or asymmetric current risk.
DATASHEET · GUIDE · APPLICATION NOTE
FREQUENTLY ASKED QUESTIONS
RELATED INSIGHTS
// end of index · 01 / 01