Sensata | Gigavac · PRODUCT SERIES

SPST-NC High Voltage Relays — Single-Pole, Normally-Closed Contact

11 models · 5-70 kVdc switching · 5-100 A continuous · Hermetic / vacuum construction · Fail-safe isolation, interlock, fault disconnect

The GIGAVAC SPST-NC family delivers single-pole, normally-closed (1 Form B) high voltage relays. The circuit stays closed while the coil is de-energised and opens on energisation — the canonical switching element for fail-safe isolation, safety interlocks and fault-driven automatic disconnection.
Hermetic / vacuum construction enables a wide switching range from 5 kVdc up to 70 kVdc and continuous current from 5 A to 100 A. Coil options include 12 / 26.5 / 115 Vdc with bus wire, turret terminal and flying leads variants.
Where an SPST-NO or latching variant of the same frame exists, the model card shows a cross-link; the configurator generates the original Sensata part-no automatically based on contact / coil / mount selections.
Fail-Safe IsolationSafety InterlockHV Fault DisconnectEmergency Stop CircuitsEV Battery ProtectionHipot / Insulation TestingX-Ray & Medical DevicesScientific Instrumentation
SERIES CERTIFICATIONS09APPROVALS
  • UL1604
  • IP67
  • IP69K
  • SAE J1171
  • ISO8846
  • RoHS
  • cRUus
  • CE
  • EPIC®

Certifications vary by model — see the corresponding model datasheet for details.

REFERENCE SPECIMENSPST-NC · 01
GIGAVAC SPST-NC HV relays — original product photo from the manufacturer's own G41B SPST-NC datasheet; family-level, the SPST-NO (G20) image was not used
HERMETIC · 1 FORM BSPST-NC HV RELAYSENSATA
GIGAVAC SPST-NC HV relays — original product photo from the manufacturer's own G41B SPST-NC datasheet; family-level, the SPST-NO (G20) image was not used
Models
11
Products
126
01Max. Switching Voltage
70 kVdc
02Max. Continuous Current
100 A
03Contact Configuration
1 Form B · NC
04Model Count
11 models
SHARED ACROSS ALL MODELSContact Form:SPST-NCCoil Voltage:12 / 26.5 / 115 VdcConnection Types:Bus Wire · Turret · Flying Leads · SolderMounting:Through-panel · Flange · Threaded · StdConstruction:Hermetic / vacuum ceramic body
01

SPST-NC Series 1 form b Contactor Models

Sorted by current rating (150A → 1000A)

11 MODELS126 PRODUCTS
CONFIGURATORMODEL↑ currentContact Voltage (kV)Continuous Current (A)Mounting TypesPDF
G41B
5kV30—Datasheet (PDF) — G41B
G47B
8kV12—Datasheet (PDF) — G47B
G43B
10kV25—Datasheet (PDF) — G43B
G81B
10kV5/10—Datasheet (PDF) — G81B
G30
25kV100—Datasheet (PDF) — G30
G32
25kV45—Datasheet (PDF) — G32
G38
25kV15—Datasheet (PDF) — G38
G62B
25kV18—Datasheet (PDF) — G62B
G61B
35kV10—Datasheet (PDF) — G61B
G64B
50kV10—Datasheet (PDF) — G64B
G71B
70kV10—Datasheet (PDF) — G71B
MODEL CONFIGURATOR · SPST-NC
LIVE

STEP-BY-STEP CONFIGURATION

Haven't picked a model from the table? Configure from scratch

Pick token by token following the manufacturer's coding table; we'll generate the exact part number and open a tailored datasheet.

BELOW · LIVE PREVIEW

TECHNICAL DIFFERENTIATORS

Why SPST-NC Series?

Flexible Coil Configuration

  • 12 / 24 / 48 / 110 Vdc coil

    Directly compatible with industrial and mobile DC bus voltages.

  • Optimised for continuous hold-open

    Coil thermal design is rated for sustained energised operation.

Fail-Safe Closed State

  • Closed on coil power loss

    Natural fit for default-on power paths and continuously active auxiliary lines.

  • Break on command

    Opens only when the supervisory system commands — ideal for bypass / isolation in protection coordination.

Redundant Protection Topologies

  • Form A + Form B cross-positioning

    Classic HV safety topology providing redundancy against different failure modes.

HV Hermetic Contact Chamber

  • Vacuum / gas-filled sealed design

    Arc is rapidly extinguished on opening; leakage in the closed state is minimal.

  • Wide environmental tolerance

    Independent of humidity, pressure and dust; field reliability is high.

Form B + Form Y Coverage

  • Standard Form B — common HV NC

    G41B, G47B, G43B, G61B, G64B, G71B, G81B and G62B span 5 kV — 70 kV.

  • Form Y — high-current NC

    G38 (15 A), G32 (45 A) and G30 (100 A) deliver high breaking capacity at the 25 kV class.

DATASHEET · GUIDE · APPLICATION NOTE

SPST-NC Series — Technical Resources

Datasheets

  • GIGAVAC HV Relay — SPST-NC Form B Datasheet Set (G41B, G47B, G43B, G62B, G61B, G64B, G71B, G81B)SOON
  • Form Y High-Current NC — G30, G32, G38SOON

Selection Guides

  • GIGAVAC HV Relay Selection Guide — Form A / Form B / Form Y / Form CSOON
  • NC Selection Flow — Hold-open Duration, Coil Thermal Limit, CertificationSOON

Application Notes

  • NC Relay Design for Default-On Safety Bypass LinesSOON
  • Form A + Form B Cross-Protection TopologySOON

FREQUENTLY ASKED QUESTIONS

About the SPST-NC series

RELATED INSIGHTS · SPST-NC
LIVE

RELATED INSIGHTS

Go deeper

01 ENTRIES

// end of index · 01 / 01