Skip to main content
Industrial supply network
IMB Electric
Sendyne SIM200 — main gallery photo from the manufacturer's official SIM200 Module page (series level)
B2B · PRODUCT SERIES · SENDYNE
LIVE

Sendyne · PRODUCT SERIES

Sendyne SIM200 Series (Next-Gen)

Sensata's newest next-gen IMD — 4 voltage classes (60V to 1500V), configurable warning/fault thresholds + CAN ID, UL2231 recognized, 'Always-On' monitoring

The Sensata SIM200 is the next-generation Insulation Monitoring Device (IMD) officially launched by Sensata Technologies on March 24, 2025, within their Clean Energy Solutions portfolio. Built on top of the SIM100 family (SIM100MOD, SIM100MLP); uses the same patented signal injection technology (algorithm acquired with Sendyne's 2021 acquisition by Sensata), but offers much broader voltage coverage and an expanded feature set. Key innovations over SIM100 4 voltage classes — xNx (1500V), xKx (1000V), xPx (500V), xQx (100V) — broader coverage than SIM100MOD (3 classes) and SIM100MLP (3 classes), especially in the 60-500V low-voltage range. Configurable thresholds — Warning level + fault threshold (default 100Ω/V) + CAN ID can be programmed by the customer. Dedicated digital fault state output — 1× digital out + 1× PWM out — fault/warning signaling without dependence on the CAN bus. Separate path for ECU/system safety layer. Internal IMD error output — Separate digital signaling when the module itself fails — reduces "silent fault" risk. UL2231 recognized — On UL's official recognized safety standard list. Patented technology SIM200 uses Sendyne's patented signal injection and dynamic self-calibration algorithm (US Pat. 8,373,408 · 8,350,552 · 8,289,030). The algorithm injects small voltages onto positive and negative high-voltage rails through isolation resistors, detecting both resistive leakages and capacitively stored energy. Operates even when the system is inactive. 4 voltage class details xNx — Application Voltage 1363 V (max 1568 V), Measurement Range ±1652 V, Input Impedance 2720 kΩ, Total Y-Cap 1.2 µF (max 4.2 µF). xKx — Application Voltage 1000 V (max 1150 V), Measurement Range ±1186 V, Input Impedance 2720 kΩ, Total Y-Cap 1.2 µF (max 4.2 µF). xPx — Application Voltage 510 V (max 582 V), Measurement Range ±608 V, Input Impedance 1000 kΩ, Total Y-Cap 4.2 µF (max 14.2 µF). xQx — Application Voltage 140 V (max 161 V), Measurement Range ±167 V, Input Impedance 272 kΩ, Total Y-Cap 6.2 µF (max 14.2 µF). Performance (response times) Initial isolation estimate: 4.5 – 5.5 seconds (system startup) Warning condition response (500 Ω/V): 4.3 – 5 seconds Fault condition response (100 Ω/V): 5.3 – 5.8 seconds Short condition detection: Max 6.5 seconds Measurement update period: 250 ms (SIM100 uses 500 ms — 2× faster) Typical applications DC fast charging stations (50-350 kW, megawatt mega charging) EV, hybrid vehicles, and commercial electric vehicle power systems Modern 800V EV platforms (Porsche Taycan, Hyundai Ioniq 5, Kia EV6) — xKx class 1500V mega-watt energy storage systems (ESS) — xNx class 500V industrial DC systems — xPx class 48V/96V auxiliary and low-voltage EVs — xQx class
DC fast-charging stations (50-350 kW, megawatt mega charging)Modern 800V EV platforms (Taycan, Ioniq 5, EV6) — xKx class1500V mega-watt energy storage systems (ESS) — xNx class500V industrial DC systems and PV inverters — xPx class48V/96V auxiliary and low-voltage EVs — xQx classHybrid vehicles and commercial electric vehicles (e-bus, e-truck)Microgrid and grid-tied DC system safety monitoring
01type
Yeni nesil IMD — 'Always-On' aktif izleme, 4 voltaj sınıfı
02launch
Sensata Mart 2025 — Clean Energy Solutions portföyü
03communication
Modüler CAN 2.0B, 500 veya 250 kbit/s, 120Ω opsiyonel termination
04operating temp
-40°C / +85°C
05Supply Voltage
9 – 30V (typ 12-24V), 60 mA @12V / 28 mA @24V
06digital outputs
1× digital fault state + 1× PWM + 1× internal error
07voltage classes
xNx (1500V) / xKx (1000V) / xPx (500V) / xQx (100V)
08capacitance range
0.2 – 1 µF reporting (±10% accuracy)
09measurement update
250 ms (SIM100'ün 2 katı hızlı)
10first estimate time
4.5 – 5.5 saniye
11isolation accuracy typ
±5% (xNx/xKx/xPx), ±3% (xQx) — UL2231 recognized
12isolation reporting range
0 – 2720 kΩ (xNx/xKx), 0 – 1000 kΩ (xPx), 0 – 272 kΩ (xQx)
01

SIM200 Series (Next-Gen) Series Contactor Models

Sorted by current rating (150A → 1000A)

4 MODELS
MODEL↑ currentcommunicationordering notevoltage classdigital outputsproduct page urlfirst estimate max sinput impedance kohmshort reporting kohmshort response max stypical applicationssupply current 24v maapplication voltage max vapplication voltage min vapplication voltage typ vvoltage measurement min vvoltage measurement typ vtotal y capacitance max uftotal y capacitance min uftotal y capacitance typ uflow voltage mode short kohmmeasurement resolution kohmisolation reporting max kohmmeasurement accuracy max pctmeasurement accuracy typ pct
CAN 2.0B (500 veya 250 kbit/s)Tam SKU kodu için Sensata datasheetxKx — 1000V (Orta-Yüksek Voltaj, 800V EV platform optimum)1× digital + 1× PWM——27208—800V EV (Taycan, Ioniq 5, EV6), 1000V DC hızlı şarj, mega charging—11506001000±1168±11864.20.21.216—2720±15±5
CAN 2.0B (500 veya 250 kbit/s, 120Ω opsiyonel termination)Tam SKU kodu için Sensata datasheet (CAN hızı + termination + threshold varyantları)xNx — 1500V (Yüksek Voltaj)1× digital fault state + 1× PWMhttps://www.sensata.com/products/insulation-monitoring-devices/sim200-module5.5272086.51500V mega-watt ESS, 1000V+ EV platformları, mega charging28156810001363±1627±16524.20.21.21612720±15±5
CAN 2.0B (500 veya 250 kbit/s)Tam SKU kodu için Sensata datasheetxPx — 500V (Orta Voltaj, 400V EV ve endüstri DC)1× digital + 1× PWM——10001.5—400V EV (Model 3, Leaf, BYD), 500V endüstri DC, PV inverter—582300510±599±60814.20.94.23—1000±15±5
CAN 2.0B (500 veya 250 kbit/s)Tam SKU kodu için Sensata datasheetxQx — 100V (Düşük Voltaj, 48V/96V yardımcı sistemler)1× digital + 1× PWM——2720.4—48V hibrit araç, 96V e-bike/e-skuter, kırsal solar DC mini-grid—16160140±164±16714.226.20.8—272±5±3 (xQx en yüksek doğruluk)

TECHNICAL DIFFERENTIATORS

Why SIM200-SERISI Series?

Dedicated Fault Outputs + Self-Diagnosis

  • Dedicated digital + PWM fault output

    CAN-independent safety layer.

  • Internal IMD error signal

    'Silent fault' risk reduced.

Configurable Thresholds + Modular CAN 2.0B

  • Configurable warning/fault thresholds

    System-specific tuning (medical-sensitive, industrial-tolerant).

  • Configurable CAN ID

    Prevents ID conflicts in multi-IMD systems.

4 Voltage Classes — Wide Coverage (60V – 1500V)

  • 4 voltage classes standard

    60V to 1500V — coverage for all EV/ESS markets.

  • 800V EV xKx standard

    Optimum for modern Porsche Taycan, Ioniq 5, EV6.

'Always-On' Continuous Monitoring + UL2231 Recognized

  • Active monitoring even with system off

    Leakage detection while parked, status known before charge initiation.