PyroFuse Series — Pyrotechnic HV DC Circuit Breaker<1 ms

STPS500 · 500 A continuous · 1000 V · 16-20 kA breaking · <1 ms interrupt · External trigger · Bidirectional · Single-shot, irreversible

Sensata PyroFuse is a pyrotechnic-based high voltage DC circuit breaker that irreversibly disconnects the circuit in under 1 millisecond on an external trigger signal. During a short-circuit or crash a small pyrotechnic charge severs the main conductor; the arc is rapidly extinguished and the battery / driver remain safe.
The available STPS500 model carries 500 A continuous with 20 kA breaking at 500 V or 16 kA at 1000 V; its bidirectional design breaks identically in both current directions. It is actuated by the EV BMS / pyro-trigger circuit and needs no external sensing electronics.
It is single-shot — replacement is mandatory after activation. This makes it the choice as a maximum safety barrier in EV and ESS systems where nuisance-trip tolerance is low and crash / short-circuit protection is critical. For a resettable alternative see the FaultBreak family.
EV Battery Pack ProtectionEV Crash HV DisconnectDC Fast Charging StationsAerospace & Defense PowerIndustrial High-Power DC BusRailway Emergency DisconnectMaritime / Off-grid HV SystemsMilitary / Defense DC Power
SERIES CERTIFICATIONS09APPROVALS
  • UL1604
  • IP67
  • IP69K
  • SAE J1171
  • ISO8846
  • RoHS
  • cRUus
  • CE
  • EPIC®

Certifications vary by model — see the corresponding model datasheet for details.

01Continuous Current
500 A
02Voltage Rating
1000 V
03Breaking Capacity
20 kA @ 500 V · 16 kA @ 1000 V
04Interrupt Time
<1 ms
01

PyroFuse Series Pyrotechnic Contactor Models

Sorted by current rating (150A → 1000A)

1 MODELS1 PRODUCTS
CONFIGURATORMODELcurrentFunctionContinuous Current (A)Rated Voltage (V)Interrupt Time (ms)MountingExample PNCoding Pattern
STPS500
Aktif (Pirotek)5001000<1STPS500STPS500 + [Tetikleme] + [Mount]
MODEL CONFIGURATOR · PYROFUSE
LIVE

STEP-BY-STEP CONFIGURATION

Haven't picked a model from the table? Configure from scratch

Pick token by token following the manufacturer's coding table; we'll generate the exact part number and open a tailored datasheet.

BELOW · LIVE PREVIEW

TECHNICAL DIFFERENTIATORS

Why PyroFuse Series?

High Breaking Capacity

  • 20 kA @ 500 V · 16 kA @ 1000 V

    Protects vehicle and system even in full-battery short-circuit scenarios.

  • Bidirectional — direction-independent protection

    Identical performance in both current directions on battery charge/discharge lines.

Sub-Millisecond Irreversible Interrupt

  • <1 ms interrupt time

    Fastest opening across all DC protection tiers; for crash and large short-circuit scenarios.

  • Mechanical irreversibility

    Re-conduction is impossible after activation; absolute disconnect guarantee.

Maximum Safety Barrier

  • Final tier in premium EV protection architectures

    Positioned alongside resettable layers (GigaFuse / FaultBreak); engaged only on real fault / crash conditions.

  • Aerospace / defense-class safety

    Compact body, wide temperature range and design intent for heavy-duty service environments.

System-Controlled Opening

  • BMS / vehicle-controller triggered

    Crash detection, thermal-runaway and other supervisory decisions can be folded into the trigger.

  • Standard pyro-trigger circuit

    Simple, low-power trigger interface compatible with mainstream EV BMS ecosystems.

Service and Lifecycle

  • Single-shot — replacement after trigger

    One-time service cost in exchange for absolute safety guarantee; nuisance-trip risk is absorbed by the resettable tier.

  • Resettable alternative: FaultBreak

    Where resettable protection is desired, the FaultBreak family is positioned instead.

DATASHEET · GUIDE · APPLICATION NOTE

PyroFuse Series — Technical Resources

Datasheets

  • STPS500 PyroFuse Datasheet — 500 A · 1000 V · 16-20 kA breaking · <1 ms interruptSOON

Selection Guides

  • GIGAVAC Contactors & Fuses Selection Guide (2026)SOON
  • EV High Voltage Protection Architectures — Passive Fuse + Pyrotechnic TierSOON

Application Notes

  • PyroFuse Pyro-Trigger Circuit and BMS IntegrationSOON
  • PyroFuse vs FaultBreak — Which Tier in Which Scenario?SOON

FREQUENTLY ASKED QUESTIONS

About the PyroFuse series