Skip to main content
Industrial supply network
IMB Electric
GLVAC Vacuum Interrupter for AC Contactor — AC vacuum contactor manufacturers (OEM component)
B2B · PRODUCT SERIES · GLVAC
LIVE

GLVAC · PRODUCT SERIES

GLVAC Vacuum Interrupter for AC Contactor

1.14-12 kV, 125A-2500A core component of AC vacuum contactors — TJ series vacuum interrupter tubes

The GLVAC TJ Series vacuum interrupter tubes are the core element of AC vacuum contactors. The high vacuum inside the tube (below 10⁻⁴ Pa pressure) extinguishes the arc within milliseconds after the medium-voltage circuit is interrupted — since this occurs in vacuum, no external magnetic blowout, gas fill, or oil insulation is required.
24 models span 5 voltage classes: 1.14 kV (8 models: 125-1250 A), 1.5 kV (1 model: 800 A), 3.6 kV (9 models: 400-2500 A), 7.2 kV (3 models: 400-800 A), 12 kV (3 models: 400-1250 A). Each model offers 100 rated switching cycles (Rated Short-Current Times: 100), 25 breaking cycles (Rated Breaking Times: 25), and 3 limited breaking cycles (Limited Breaking Times: 3).
Typical customers: AC contactor manufacturers (those making CKJ5, CKJ11, CV/CHV, 7.2 kV, and 12 kV series), industrial switchgear manufacturers, and OEM electrical panel manufacturers. Not for individual end-users — sold as components within complete AC vacuum contactor products.
AC vacuum contactor manufacturers (OEM component)CKJ5, CKJ11, CV/CHV, 7.2/12 kV series manufacturingIndustrial switchgear manufacturersOEM electrical panel manufacturingMagnetic starter (DOL starter) manufacturing
01type
AC kontaktör çekirdek bileşeni vakum kesici tüpü
02Current Range
125 A – 2500 A nominal
03vacuum pressure
10⁻⁴ Pa altı (yüksek vakum)
04voltage classes
1.14 / 1.5 / 3.6 / 7.2 / 12 kV (5 sınıf)
05rated short times
100 çevrim
06withstand voltage
10-48 kV (1 dakika güç frekansı dayanım)
07rated breaking times
25 çevrim
08limited breaking times
3 çevrim
01

Vacuum Interrupter for AC Contactor Series Contactor Models

Sorted by current rating (150A → 1000A)

24 MODELS
MODEL↑ currentrated current arated voltage kvrated short currentwithstand voltage kvrated breaking capacitylimited breaking capacity
10001.1410 kA/100108 kA/258 kA/3
12501.1412.5 kA/1001010 kA/2512 kA/3
1251.141.25 kA/100101 kA/252 kA/3
1601.141.6 kA/100101.28 kA/252 kA/3
1601.141.6 kA/100101.28 kA/252 kA/3
4001.144 kA/100103.2 kA/254.5 kA/3
5001.145 kA/100104 kA/256 kA/3
6301.146.3 kA/100105 kA/256 kA/3
8001.58 kA/100126.4 kA/258 kA/3
12501212.5 kA/100420.412.5 kA/3
400124 kA/100483.2 kA/254.5 kA/3
630126.3 kA/100425 kA/256.3 kA/3
12503.612.5 kA/100100.412.5 kA/3
16003.616 kA/1001812.8 kA/2516 kA/3
17503.617.5 kA/1001014 kA/2517.5 kA/3
25003.625 kA/1001020 kA/2525 kA/3
4003.64 kA/100183.2 kA/254.5 kA/3
4003.64 kA/100183.2 kA/254.5 kA/3
5003.65 kA/100184 kA/255 kA/3
6303.66.3 kA/100185 kA/256.3 kA/3
8003.68 kA/100106.4 kA/258 kA/3
4007.24 kA/100203.2 kA/256 kA/3
6307.26.3 kA/100285 kA/256.3 kA/3
8007.28 kA/100256.4 kA/259 kA/3

TECHNICAL DIFFERENTIATORS

Why AC-KONTAKTOR-ICIN-VAKUM-KESICI Series?

High Vacuum Insulation

  • Below 10⁻⁴ Pa vacuum

    → Arc extinguishes in milliseconds.

  • No external blowout/gas/oil

    → Eco-friendly, silent.

Wide Voltage and Current Coverage

  • 5 voltage classes (1.14-12 kV)

    → From mining to city distribution.

  • 125-2500 A rated current

    → All AC contactor power classes.

OEM Contactor Manufacturer Compatibility

  • Compatible with GLVAC's own series

    → CKJ5, CKJ11, CV/CHV, 7.2/12 kV.

  • Third-party OEM compatibility

    → China/Türkiye/India/LATAM markets.

DATASHEET · GUIDE · APPLICATION NOTE

AC-KONTAKTOR-ICIN-VAKUM-KESICI Series — Technical Resources

TJ-1.14/125D Datasheet

  • TJ-1.14/125D DatasheetSOON

TJ-1.14/160G Datasheet

  • TJ-1.14/160G DatasheetSOON

TJ-1.14/160B Datasheet

  • TJ-1.14/160B DatasheetSOON

TJ-1.14/400D Datasheet

  • TJ-1.14/400D DatasheetSOON

TJ-1.14/500A Datasheet

  • TJ-1.14/500A DatasheetSOON

TJ-1.14/630 Datasheet

  • TJ-1.14/630 DatasheetSOON

TJ-1.14/1000B Datasheet

  • TJ-1.14/1000B DatasheetSOON

TJ-1.14/1250A Datasheet

  • TJ-1.14/1250A DatasheetSOON

TJ-1.5/800A Datasheet

  • TJ-1.5/800A DatasheetSOON

TJ-3.6/400D Datasheet

  • TJ-3.6/400D DatasheetSOON

TJ-3.6/400E Datasheet

  • TJ-3.6/400E DatasheetSOON

TJ-3.6/500A Datasheet

  • TJ-3.6/500A DatasheetSOON

TJ-3.6/630B Datasheet

  • TJ-3.6/630B DatasheetSOON

TJ-3.6/800C Datasheet

  • TJ-3.6/800C DatasheetSOON

TJ-3.6/1250B Datasheet

  • TJ-3.6/1250B DatasheetSOON

TJ-3.6/1600A Datasheet

  • TJ-3.6/1600A DatasheetSOON

TJ-3.6/1750 Datasheet

  • TJ-3.6/1750 DatasheetSOON

TJ-3.6/2500B Datasheet

  • TJ-3.6/2500B DatasheetSOON

TJ-7.2/400D Datasheet

  • TJ-7.2/400D DatasheetSOON

TJ-7.2/630B Datasheet

  • TJ-7.2/630B DatasheetSOON

TJ-7.2/800A Datasheet

  • TJ-7.2/800A DatasheetSOON

TJ-12/400A Datasheet

  • TJ-12/400A DatasheetSOON

TJ-12/630I Datasheet

  • TJ-12/630I DatasheetSOON

TJ-12/1250 Datasheet

  • TJ-12/1250 DatasheetSOON

FREQUENTLY ASKED QUESTIONS

About the AC-KONTAKTOR-ICIN-VAKUM-KESICI series

RELATED INSIGHTS · AC-KONTAKTOR-ICIN-VAKUM-KESICI
LIVE

RELATED INSIGHTS

Go deeper

02 ENTRIES

// end of index · 02 / 02