SIM100MLP-ALA

Modular IMD — 100/1100/1500V voltage classes, 60×50×22.9 mm compact, 12 SKU variants, optional CAN termination

CUSTOMER ACTIONS
SIGN IN →

SERIES FAMILY IMAGE

FAMILY IMAGE
Sendyne SIM100MLP — main gallery photo from the manufacturer's official SIM100MLP Module page; the page marks it Obsolete (no stock/production claim)

Sendyne SIM100MLP — main gallery photo from the manufacturer's official SIM100MLP Module page; the page marks it Obsolete (no stock/production claim)

TECHNICAL DOCUMENTS

SIM100MLP Series series

SIM100MLP Series Datasheet

Datasheet coming soon

—

3D STEP Model

STEP file on request

—
B2B · SENDYNE · TECHNICAL BRIEF
LIVE

ABOUT SIM100MLP SERIES

Series overview

View full series

The Sendyne SIM100MLP is the modular and flexible version of SIM100MOD. Operates with the same patented signal injection and dynamic self-calibration algorithm; offers 100V, 1100V, or 1500V voltage class options. CAN 2.0B isolated interface (500 or 250 kbit/s), optional 120Ω termination resistor. All Molex connectors included (2.54 mm pitch, right-angle header). Compact 60×50×22.9 mm size. +4.8 V to +53 V supply, <375 mW (5V) / <475 mW (48V) power consumption. Operation -40°C / +125°C (electronics), -40°C / +105°C (with connectors). 12 SKU variants: xKx (1100V) standard, xLx (100V) and xNx (1500V) special order. Compliant with ISO 6469-3:2011-12, UL 2231-1, UL 2231-2, IEC 61557-8, CFR 571.305.

The Sendyne SIM100MLP is the modular form-factor version of the SIM100MOD family — MLP = Modular Low Profile. Operates with the same patented isolation monitoring algorithm (US Pat. 8,373,408 · 8,350,552 · 8,289,030), but offers a higher voltage class (1100V xKx) and different connector configuration.

Key differences from SIM100MOD:

  • Voltage class: SIM100MOD has xMx (960V), SIM100MLP has xKx (1100V) — broader mid-to-upper voltage coverage.
  • Connector pitch: SIM100MOD 2.00 mm through-hole, SIM100MLP 2.54 mm right-angle — easier PCB and panel integration.
  • Connector options: SIM100MOD offers 4 (A/B/C/D); SIM100MLP offers 2 (A/B) — connectorized only.
  • Modular design: Compact 60×50×22.9 mm form factor, optimized for modular integration.

Battery-connected VX1 (Vp) and VX2 (Vn) voltage inputs can measure ±1500V (xNx), ±1100V (xKx), or ±100V (xLx) with respect to chassis (0V). Detects both resistive leakages and capacitively stored energy. Insulation resistance changes are detected in under 5 seconds; measurement updates occur every 500 ms.

The module continues to produce accurate results even when the system voltage drops below 15V or the battery is not connected.

Typical applications:

  • Monitoring ungrounded (IT) DC power systems for hazardous resistive and capacitive leaks
  • Electric and hybrid vehicles (EV/HEV/PHEV)
  • DC fast-charging stations (CCS, CHAdeMO compatible)
  • Energy storage facilities (ESS) and microgrid
  • Battery management systems (BMS)

Ordering matrix (12 SKU): CAN speed (A=500 kbit/s, B=250 kbit/s) × Voltage class (L=100V special, K=1100V standard, N=1500V special) × Connectors (A=all connectors + termination, B=all connectors, no termination).

APPLICATION AREAS

6
Monitoring ungrounded (IT) DC power systems for hazardous leaksElectric vehicle (EV) and hybrid vehicle (HEV/PHEV) — 400V and 800V platformsDC fast-charging stations (50-350 kW, CCS/CHAdeMO)Modular energy storage (ESS) and microgrid installationsBattery management system (BMS) safety layerOEM product integration (modular form, space-constrained)

QUOTE FOR THIS MODEL