HV Vacuum / Gas-Filled Technology
Hermetically sealed contact chamber
Consistent arc extinction independent of ambient humidity, pressure or dust.
High dielectric strength
Minimises leakage in the open state — critical for HV safety coordination.

Sensata | Gigavac · PRODUCT SERIES
15 models · 5-70 kVdc switching · 5-110 A continuous · Hermetic / vacuum construction · Test equipment, ATE, energy routing
Certifications vary by model — see the corresponding model datasheet for details.

SPST-NO High Voltage Relays / Form A Contact
| CONFIGURATOR | MODEL↑ current | Contact Voltage (kV) | Continuous Current (A) | Mounting Types | |
|---|---|---|---|---|---|
G41A | 5kV | 30 | 3-hole Flange, Std Flange | Datasheet (PDF) — G41A | |
CONFIGURATOR · G41AMODEL-SPECIFIC | |||||
G47A | 8kV | 12 | 3-hole Flange, Std Flange | Datasheet (PDF) — G47A | |
G43A | 10kV | 25 | 3-hole Flange, Std Flange | Datasheet (PDF) — G43A | |
G81A | 10kV | 5/10 | Panel Mount, PC Board | Datasheet (PDF) — G81A | |
G22 | 25kV | 65 | Through Panel | Datasheet (PDF) — G22 | |
G28 | 25kV | 30 | Through Panel | Datasheet (PDF) — G28 | |
G62A | 25kV | 18 | Threaded | Datasheet (PDF) — G62A | |
G20 | 28kV | 110 | Through Panel | Datasheet (PDF) — G20 | |
G61A | 35kV | 10 | Threaded | Datasheet (PDF) — G61A | |
G64A | 50kV | 10 | Threaded | Datasheet (PDF) — G64A | |
G71A | 70kV | 10 | Threaded | Datasheet (PDF) — G71A | |
Latching Models
2 models · Holds state without continuous coil power
| CONFIGURATOR | MODEL | Contact Voltage (kV) | Continuous Current (A) | Mounting Types | |
|---|---|---|---|---|---|
G61LA | 35kV | 10 | — | Datasheet (PDF) — G61LA | |
G71LA | 70kV | 10 | — | Datasheet (PDF) — G71LA |
TECHNICAL DIFFERENTIATORS
Hermetically sealed contact chamber
Consistent arc extinction independent of ambient humidity, pressure or dust.
High dielectric strength
Minimises leakage in the open state — critical for HV safety coordination.
5 kV — 70 kV voltage range
From low HV (G81A, G47A) to ultra-high voltage (G71A) under the same contact philosophy.
5 — 110 A continuous current scale
Single family covering test equipment (G81A, 5/10 A) up to main power (G20, 110 A).
G61LA · G71LA pulse-latching
For low-power, portable or battery-backed HV systems where continuous coil energy is undesirable.
Open on coil power loss
System defaults to safe disconnect — natural fit for main HV switches.
Conduction on command
Closes the circuit only when the supervisory system explicitly commands it.
12 / 24 / 48 / 110 Vdc coil options
Directly compatible with common industrial and mobile DC bus voltages.
Economiser / pull-in profiles
On selected models hold-current is reduced for lower long-term coil consumption.
DATASHEET · GUIDE · APPLICATION NOTE
FREQUENTLY ASKED QUESTIONS
RELATED INSIGHTS
// end of index · 01 / 01